AIRGAS -- HYDROGEN -- 6830-00N075377
=====================  Product Identification  =====================

Product ID:HYDROGEN
MSDS Date:05/01/1990
FSC:6830
NIIN:00N075377
=== Responsible Party ===
Company Name:AIRGAS
Address:5 RADNOR CORP CENTER, 100 MATSONFORD RD
City:RADNOR
State:PA
ZIP:19087
Country:US
Info Phone Num:215-687-5253
Emergency Phone Num:215-687-5253
CAGE:AIRGA
=== Contractor Identification ===
Company Name:AIRGAS
Address:100 MATSONFORD ROAD, 5 RADNOR CORP CNTR
City:RADNOR
State:PA
ZIP:19087
Country:US
Phone:215-687-5253
CAGE:AIRGA
Company Name:AIRGAS INC
Address:100 MATSONFORD RD SUITE 550
Box:City:WAYNE
State:PA
ZIP:19087
Country:US
Phone:215-687-5253
CAGE:0MN39

=============  Composition/Information on Ingredients  =============

Ingred Name:HYDROGEN
CAS:1333-74-0
RTECS #:MW8900000
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPP DATA:BE MOVED TO UNCONTAM AREA, GIVEN MOUTH-TO-MOUTH
    RESUSCITATION & SUPP OXYG. FURTHER TREATMENT SHOULD BE (ING 3)
RTECS #:9999999ZZ

Ingred Name:ING 2:SYMPTOMATIC & SUPPORTIVE.
RTECS #:9999999ZZ

Ingred Name:OTHER PREC:USE CHECK VALVE/TRAP IN DISCHARGE LINE TO PVNT
    HAZ BACK FLOW INTO CYL. PROT CYLS FROM PHYSICAL DMG. (ING 5)
RTECS #:9999999ZZ

Ingred Name:ING 4:STORE IN COOL, DRY, WELL-VENTED AREA OF NONCOMBUST
    CONSTRUCTION AWAY FROM HEAVILY TRAFFICKED AREAS & EMER (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5:EXITS. DO NOT ALLOW TEMP WHERE CYLS ARE STORED TO
    EXCEED 130F(54C). CYLS SHOULD BE STORED UPRIGHT & FIRMLY (ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:SECURED TO PVNT FALLING/BEING KNOCKED OVER. FULL &
    EMPTY CYLS SHOULD BE SEGREGATED. USE "FIRST IN-FIRST (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:OUT" INVENTORY SYS TO PVNT FULL CYLS BEING STORED FOR
    EXCESSIVE PERIODS OF TIME. POST "NO SMOKING/OPEN (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:FLAMES" SIGNS IN STOR/USE AREA. THERE SHOULD BE NO
    SOURCES OF IGNIT IN STOR/USE AREA. FOR ADDNL HNDLG/STOR(ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:RECS, CONSULT COMPRESSED GAS ASSOC'S PAMPHLETS G-5,
    P-1, P-14 & SFTY BULLETIN SB-2. HYDROGEN IS NONCORR (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:& MAY BE USED W/ANY COMMON STRUCTURAL MATL.
    EARTH-GROUND & BOND ALL LINES & EQUIP ASSOC W/HYDROGEN SYS. (ING
    12)
RTECS #:9999999ZZ

Ingred Name:ING 11:ELEC EQUIP SHOULD BE NON-SPARKING/EXPLO PROOF.
    COMPRESSED GAS CYLS SHOULD NOT BE REFILLED EXCEPT BY (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:QUALIFIED PRDCRS OF COMPRESSED GASES. SHIPMENT OF
    COMPRESSED GAS CYL WHICH HAS NOT BEEN FILLED BY OWNER/ (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:WITH HIS (WRITTEN) CONSENT IS A VIOLATION OF FED LAW
    (49 CFR). ALWAYS SECURE CYLS IN UPRIGHT POS BEFORE (ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14:TRANSPORTING THEM. NEVER TRANSPORT CYLS IN TRUNKS OF
    VEHICLES, ENCLSD VANS, TRUCK CABS/IN PASSENGER (ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15:COMPARTMENTS. TRANSPORT CYLS SECURED IN OPEN FLATBED
    OR IN OPEN PICK-UP TYPE VEHICLES.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:HYDROGEN IS DEFINED AS A SIMPLE
    ASPHYXIANT. OXYGEN LEVELS SHOULD BE MAINTAINED AT >18 MOLAR PERCENT
    AT NORMAL ATMOSPHERIC PRESSURE WHICH IS EQUIVALENT TO PARTIAL
    PRESSURE OF 135 MM HG. INHALATION:HIGH  CONCENTRATIONS OF HYDROGEN
    SO AS TO EXCLUDE ADEQUATE SUPPLY OF OXYGEN TO LUNGS CAUSES
    DIZZINESS, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DEEPER BREATHING DUE TO AIR HUNGER,
    POSSIBLE NAUSEA & EVENTUAL UNCONSCIOUSNESS. HYDROGEN IS INACTIVE
    BIOLOGICALLY & ESSENTIALLY NONTOXIC; THEREFORE, MAJOR PROPERTY IS
    EXCLUSION OF ADEQUATE SU PPLY OF OXYGEN TO LUNGS.
Medical Cond Aggravated by Exposure:PERSONS IN ILL HEALTH WHERE SUCH
    ILLNESS WOULD BE AGGRAVATED BY EXPOSURE TO HYDROGEN SHOULD NOT BE
    ALLOWED TO WORK WITH OR HANDLE THIS PRODUCT.

=======================  First Aid Measures  =======================

First Aid:PROMPT MED ATTN IS MANDATORY IN ALL CASES OF OVEREXP TO
    HYDROGEN. RESCUE PERS SHOULD BE EQUIPPED W/NIOSH APPRVD SCBA & BE
    COGNIZANT OF EXTREME FIRE & EXPLO HAZ. INGEST:CALL MD IMMED .
    EYES:IMMED	FLUSH W/POTABLE WATER FOR MIN OF 15 MINS, SEEK
    ASSISTANCE FROM MD . SKIN:FLUSH W/COPIOUS AMTS OF WATER. CALL MD .
    INHAL:CONSCIOUS PERS SHOULD BE ASSISTED TO UNCONTAM AREA &
    INHALE(SUPDAT)

=====================  Fire Fighting Measures  =====================

Flash Point:GAS
Lower Limits:4%
Upper Limits:74.5%
Extinguishing Media:WATER, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP . IF
    POSS, STOP FLOW OF HYDROGEN. COOL SURROUND CNTNRS W/WATER SPRAY.
    HYDROGEN BURNS W/ALMOST INVISIBLE (SUPDAT)
Unusual Fire/Explosion Hazard:HYDROGEN IS FLAMM OVER VERY WIDE RANGE IN
    AIR. HYDROGEN IS VERY LIGHT & RISES VERY RAPIDLY IN AIR. SHOULD
    HYDROGEN FIRE BE EXTING & FLOW OF GAS (SUPP DATA)

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREA. USE
    APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE
    PIPING W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN CNTNR
    VALVE, CONT YOUR CLOSES T SUPPLIER LOCATION/CALL EMER TELEPHONE#
    LISTED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:FLAMMABLE GAS. USE ONLY IN WELL-VENTED
    AREAS. VALVE PROT CAPS MUST REMAIN IN PLACE UNLESS CNTNR IS SECURED
    W/VALVE OUTLET PIPED TO USE POINT.
Other Precautions:DO NOT DRAG, SLIDE/ROLL CYLS. USE SUITABLE HAND TRUCK
    FOR CYL MOVEMENT. USE PRESS REDUCING REGULATOR WHEN CONNECTING CYL
    TO LOWER PRESS (<3,000 PSIG) PIPING/SYS. DO NOT HEAT CYL BY ANY
    MEANS TO INCR D ISCHARGE RATE OF PROD FROM CYL. (ING 4)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH APPROVED POSITIVE PRESSURE AIR LINE W/MASK
    OR SELF-CONTAINED BREATHING APPARATUS SHOULD BE AVAILABLE FOR
    EMERGENCY USE.
Ventilation:HOOD W/FORCED VENTILATION. LOCAL EXHAUST:TO PREVENT
    ACCUMULATION ABOVE LEL. MECHANICAL(GENERAL):I/A/W ELECTRICAL CODES.
Protective Gloves:PLASTIC OR RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . SAFETY SHOES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:FLAME OF RELATIVELY LOW THERMAL RADIA. EXPLO
    HAZ:CONTINUE, INCR VENT TO PVNT EXPLO HAZ, PARTICULARLY IN UPPER
    PORTIONS OF BLDGS/SHEDS WHERE GAS MIGHT "COLLECT". WASTE DISP
    METH:TELEPHO NE NUMBER LISTED. FIRST AID PROC:FRESH AIR. QUICK
    REMOVAL FROM CONTAM AREA IS MOST IMPORTANT. UNCON PERS SHOULD (ING
    2)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-423F,-253C
Melt/Freeze Pt:M.P/F.P Text:-435F,-259C
Vapor Pres:>-399.8F
Spec Gravity:0.069 (AIR=1)
Solubility in Water:VERY SLIGHTLY
Appearance and Odor:COLORLESS, ODORLESS GAS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXIDIZERS.
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DO NOT ATTEMPT TO DISP OF WASTE/UNUSED QTYS.
    RETURN IN SHIPPING CNTNR PROPERLY LABELED, W/ANY VALVE OUTLET
    PLUGS/CAPS SECURED & VALVE PROT CAP IN PLACE TO YOUR SUPPLIER. FOR
    EMER DISP ASSISTANCE, CONT	YOUR CLOSEST SUPPLIER LOCATION/CALL
    EMERG(SUPDAT)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.